VINTAGE AIR STREAMLINE 4 KNOB CONTROL PANEL ASSEMBLY (BLACK ANODIZE)
Upgrade Gen II Panels
4-Knob Gen II StreamlineTM Panels
Designed to fit into very compact dash or console positions. Internally lighted through the soft-glow aluminum knobs and delivering infinite louver air temperature regulation and bi-level operation of A/C and heat.
With simple plug-in connections, no vacuum lines and fewer wires to route, this panel operates our exclusive servo-actuated heater valve that allows the introduction of small amounts of heat to regulate air temperature.
Dimensions: 5.318-inches wide x 1 inch tall x 2.625-inches deep.
We endeavour to keep stock levels as accurate as possible. However, due to the fact we sell both online and in-store, there may be slight inconsistencies in these stock levels. To confirm stock levels, please get in touch
an ISO 9001: 2008 Registered Company
STREAMLINE
4 KNOB PANEL ANODIZED
491229
OFF LO
MED HI
H |
C |
|
901229 REV C 12/15/16, INST STREAMLINE 4 KNOB CONTROL PANEL (ANOD) PG 1 OF 11
TABLE OF CONTENTS
PAGES
1.COVER
2.TABLE OF CONTENTS
3.PACKING LIST
4.CONTROL PANEL TEMPLATE & INSTALLATION
5.INSTALLATION DIAGRAM
6.OPERATION OF CONTROLS
7.GEN II COMPAC & SUPER WIRING DIAGRAM
8.GEN II MINI WIRING DIAGRAM
9.THERMOSTAT ADJUSTMENT PAGE
10.PARTS BREAK DOWN OF CONTROL PANEL KIT
11.CONTROL PANEL KIT PACKING LIST
2
901229 REV C 12/15/16, INST STREAMLINE 4 KNOB CONTROL PANEL (ANOD) PG 2 OF 11
|
CONTROL PANEL PACKING LIST |
CONTROL PANEL |
|
||
|
491229 |
|
|||
|
|
|
|
|
|
No. |
QTY. |
PART No. |
DESCRIPTION |
|
|
|
|
|
|
|
|
1. |
1 |
491229 |
STRMLINE 4 KNOB CONTROL PANEL (ANDZ) |
|
**BEFORE BEGINNING INSTALLATION OPEN ALL PACKAGES AND CHECK CONTENTS OF SHIPMENT. PLEASE REPORT ANY SHORTAGES DIRECTLY TO VINTAGE AIR WITHIN 15 DAYS. AFTER 15 DAYS, VINTAGE AIR WILL NOT BE RESPONSIBLE FOR MISSING OR DAMAGED ITEMS.
OFF LO
MED HI
H |
C |
|
3
901229 REV C 12/15/16, INST STREAMLINE 4 KNOB CONTROL PANEL (ANOD) PG 3 OF 11
STREAMLINE 4 KNOB CONTROL PANEL TEMPLATE
TEMPLATE FOR
5.318”
4.250”
1.068”
LEVEL THIS LINE
CONTROL PANEL INSTALLATION
SELECT A SUITABLE LOCATION FOR THE CONTROL PANEL. CONSIDER HEATER CONTROL VALVE LOCATION, WIRING HARNESS LENGTH AND CAPILLARY TUBE TO EVAPORATOR DISTANCE.
AFTER SELECTING A LOCATION FOR THE PANEL, MASK THE AREA 2 ½” (TALL) x 6 ½” (WIDE).
CUT OUT TEMPLATE ABOVE AND CUT OUT THE GREY SECTION OF TEMPLATE ALONG DOTTED LINE.
BE SURE TO LEVEL TEMPLATE ON DASH.
MARK DASH WITH MARKER OR SCRIBE.
CUT OUT OPENING FOR PANEL.
REMOVE (3) CONTROL PANEL BRACKET MOUNTING SCREWS AND REMOVE THE CONTROL PANEL BRACKET WITH SWITCHES FROM CONTROL PANEL FACE. SEE FIGURE 1, PAGE 5
INSTALL FACE IN DASH AND REINSTALL CONTROL PANEL BRACKET WITH SWITCHES. SEE FIGURE 2 & 2a, PAGE 5
CONNECT THE SET OF WIRES COMING FROM THE LIGHT BULBS WITH THE RING TERMINAL TO GROUND.
CONNECT THE OTHER SET OF WIRES COMING FROM THE LIGHT BULBS WITH THE FEMALE INSULATED TERMINAL INTO THE VEHICLES HARNESS THAT POWERS YOUR INSTRUMENT PANEL LIGHTS (+12 VOLT).
WIRE THE SYSTEM AS SHOWN ON PAGE 7 FOR COMPAC & SUPER UNITS OR PAGE 8 FOR MINI UNITS.
INSERT CAPILLARY TUBE THRU THE STICKER ON TOP OF THE EVAPORATOR THE ENTIRE THICKNESS OF THE COIL. SEE PAGE 9.
4
901229 REV C 12/15/16, INST STREAMLINE 4 KNOB CONTROL PANEL (ANOD) PG 4 OF 11
FIGURE 1
OFF
LO
MED
HI
OPENING
IN DASH
OFF |
H |
C |
|
||
|
|
|
LO |
|
|
MED |
|
|
HI |
|
|
FIGURE 2
CONTROL PANEL
BRACKET w/ SWITCHES
CONTROL PANEL
FACE
H |
C |
|
NOTE: TABS MAY NEED
TO BE TRIMMED DEPENDING
ON DASH THICKNESS
DASH
BRACKET
CONTROL
PANEL SIDE VIEW
FACE
FIGURE 2a
5
901229 REV C 12/15/16, INST STREAMLINE 4 KNOB CONTROL PANEL (ANOD) PG 5 OF 11
STREAMLINE 4 KNOB
CONTROL PANEL OPERATION
FAN SPEED CAN BE OPERATED IN ANY MODE POSITION.
OFF |
H |
C |
|
LO |
|||
|
|||
|
|
||
MED |
|
|
|
HI |
|
|
SYSTEM OFF
TURNING THE FAN SPEED
KNOB TO OFF WILL SHUT
DOWN THE SYSTEM IN ANY
MODE .
OFF |
H |
C |
|
LO |
|||
|
|||
|
|
||
MED |
|
|
|
HI |
|
|
DEFROST MODE
(OPTIONAL, FOR DEFROST ONLY!)
SELECT FAN SPEED. SET MODE SWITCH TO DEFROST. TURN THE COLD AIR KNOB SLIGHTLY TO THE RIGHT, TO ENGAGE THE COMPRESSOR. TURN KNOB TO THE RIGHT TO OPEN HOT WATER VALVE TO PROVIDE HEATED DEFROST AIR.
DEHUMIDIFIED DEFROST WILL BE DIRECTED TO THE WINDSHIELD.
OFF |
H |
C |
|
LO |
|||
|
|||
|
|
||
MED |
|
|
|
HI |
|
|
A/C MODE
TURN COLD AIR KNOB TO THE RIGHT FOR COLD AIR, AND ADJUST MODE LEVER TO VENT OR
OFF |
H |
C |
|
LO |
|||
|
|||
|
|
||
MED |
|
|
|
HI |
|
|
VENT HEAT MODE
SELECT FAN SPEED. SET MODE
SWITCH TO DASH, AND TURN
THE HEAT KNOB TO THE
RIGHT FOR HEAT MODE. HOT
OFF |
H |
C |
|
LO |
|||
|
|||
|
|
||
MED |
|
|
|
HI |
|
|
SELECT FAN SPEED. SET MODE SWITCH
TO BI, FOR BI LEVEL, AND TURN THE
HEAT KNOB TO THE RIGHT FOR HEAT.
HOT AIR WILL EXIT THE DASH VENTS & FLOOR.
OFF |
H |
C |
|
LO |
|||
|
|||
|
|
||
MED |
|
|
|
HI |
|
|
FLOOR HEAT MODE
SELECT FAN SPEED. SET MODE
LEVER TO FLOOR, AND TURN THE
HEAT KNOB TO THE RIGHT FOR
HEAT MODE. HOT AIR WILL EXIT THE
FLOOR VENTS.
6
901229 REV C 12/15/16, INST STREAMLINE 4 KNOB CONTROL PANEL (ANOD) PG 6 OF 11
|
|
|
|
|
|
|
|
|
|
WIRING DIAGRAM - GEN II COMPAC/SUPER UNITS |
||||||
|
|
|
|
|
|
|
|
|
|
HEAT/COOL/DEFROST |
||||||
|
|
|
|
|
|
|
|
|
|
|
|
CONTROL PANEL |
|
|
||
|
|
(REQUIRED) COMPRESSOR |
|
|
|
|
|
|
|
YELLOW |
|
|
||||
|
|
SAFETY SWITCH |
|
A/C |
|
|
|
|
|
|
|
|
|
|||
|
|
BINARY TYPE |
BLUE |
|
|
|
|
|
|
RED |
|
|
|
|||
|
|
|
CLUTCH |
|
|
|
|
|
|
|
||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||
|
|
|
|
|
|
|
|
BLACK |
|
|
|
|
|
ORANGE |
|
|
|
|
|
|
|
|
|
|
BLUE |
MODE |
|
FAN SPEED |
|
|
|
||
|
|
|
|
|
|
|
|
|
SWITCH |
|
SWITCH |
|
|
|
||
|
|
|
|
|
A/C |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
THERMOSTAT |
|
M |
|
|
|
M |
|
|
|
|
|
|
|
|
|
|
|
|
|
L |
|
H |
L |
|
H |
|
|
|
|
|
|
|
|
|
|
|
B |
|
C |
B |
|
C |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
YELLOW |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
RED |
|
|
|
|
|
|
|
POWER |
|
|
BLUE |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
RELAY |
|
87 |
|
|
|
|
87 |
|
ORANGE |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||
|
|
|
|
|
|
|
PURPLE |
|
|
|
|
|
|
|||
|
|
|
|
|
WHITE |
|
87a |
WHITE |
|
87a |
|
|
|
|
||
|
|
|
|
|
86 |
|
|
86 |
|
|
|
|
||||
|
|
|
|
|
|
85 |
|
|
|
85 |
|
BLOWER |
WHITE |
|||
|
|
|
|
|
|
|
|
|
|
|
|
|
HIGH |
|
||
|
|
|
|
|
|
|
30 |
|
|
|
|
30 |
|
MOTOR |
GROUND |
|
|
|
|
|
|
|
|
|
|
|
|
BLOWER |
|||||
|
|
|
|
|
|
|
|
|
|
BLUE |
|
|
|
|||
|
|
|
|
|
GROUND |
|
|
|
|
|
|
RELAY |
|
|
|
|
PINK |
BLUE |
YELLOW |
GREEN |
|
|
|
|
|
|
|
|
PURPLE |
|
|
|
|
|
(OPTIONAL) |
|
RED |
|
|
|
|
|
|
|
CONNECT TO |
|||||
|
|
|
|
FOR DEFROST |
|
|
|
|
|
|
|
|
KEY ON IGNITION |
|||
|
|
|
|
|
|
|
|
|
|
|
|
|
||||
|
|
|
|
|
ONLY! |
|
|
|
|
|
|
|
|
AUX. |
|
SOURCE (5AMP FUSE) |
|
|
|
|
|
|
RED/WHITE |
|
|
RED/WHITE |
|
|
|
|
|||
|
|
|
|
|
|
|
|
HEATER CONTROL |
|
|
|
|||||
|
|
|
|
|
WHITE/YELLOW |
|
WHITE/YELLOW |
|
30 |
|
||||||
|
|
|
|
|
|
GREY/BLACK |
|
|
GREY/BLACK |
|
VALVE |
|
AMP |
|
||
|
|
|
|
|
|
|
|
POTENTIOMETER |
|
|
||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
CIRCUIT |
|||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
BREAKER |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
BAT. |
|
TO BATTERY OR |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
BATTERY TERMINAL |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
ON STARTER |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
SOLENOID. |
|
|
|
|
|
|
|
CONTROL MODULE |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
WHITE |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
GROUND |
|
GREY PURPLE |
|
|
BLACK/WHITE WHITE/ORANGE |
WHITE/BLUE WHITE/BROWN |
|
|
|
||||
|
BLACK |
ORANGE |
BROWN |
|
RED LT. BLUE |
|
|
(OPTIONAL) |
WHITE/RED |
|
|
|||||
|
|
|
|
|
|
|
|
DEFROST |
FOR DEFROST |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
ONLY! |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
SERVO |
|
|
|
HEATER CONTROL |
|
|
||
|
|
|
|
|
|
|
(REAR VIEW OF PLUG) |
|
|
|
||||||
|
|
|
|
|
|
|
|
|
VALVE SERVO |
|
|
|
||||
|
|
FLOOR/VENT |
|
|
|
|
|
|
|
|
|
|
||||
|
|
|
NOTE ORIENTATION |
|
(REAR VIEW OF PLUG) |
|
|
|||||||||
7 |
|
|
SERVO |
|
|
|
|
|
|
|||||||
|
|
|
|
|
|
|
|
|
|
|
||||||
(REAR VIEW OF PLUG) |
|
|
OF PLUGS |
|
|
|
|
|
|
|
|
|||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
901229 REV C 12/15/16, INST STREAMLINE 4 KNOB CONTROL PANEL (ANOD) PG 7 OF 11
WIRING DIAGRAM - GEN II MINI UNITS
HEAT/COOL/DEFROST
CONTROL PANEL
YELLOW
(REQUIRED) COMPRESSOR |
BLUE |
A/C |
|
CLUTCH |
|||
SAFETY SWITCH |
|
||
|
|
||
BINARY TYPE |
|
|
|
|
|
BLACK |
BLUE |
MODE |
|
|
|
|
|
SWITCH |
|
A/C |
|
|
THERMOSTAT |
M |
|
L |
H |
L |
B C B
|
|
|
POWER |
|
|
BLUE |
|
|
|
|
|
|
|
|
|
|
|
|
RELAY |
|
87 |
|
|
|
|
|
|
|
PURPLE |
|
|
|
|
|
WHITE |
|
87a |
WHITE |
|
|
|
|
86 |
|
|||
|
|
|
|
85 |
|
86 |
|
|
|
|
|
|
30 |
|
|
|
|
|
GROUND |
|
|
|
BLUE |
PINK |
BLUE YELLOW |
GREEN |
|
|
|
|
|
(OPTIONAL) |
|
RED |
|
||||
|
|
|
|
|
|||
|
|
|
FOR DEFROST |
|
|
||
|
|
|
|
|
|
||
|
|
|
ONLY! |
|
|
|
|
|
|
|
|
RED/WHITE |
|
RED/WHITE |
|
|
|
|
WHITE/YELLOW |
WHITE/YELLOW |
|||
|
|
|
|
GREY/BLACK |
|
GREY/BLACK |
CONTROL MODULE
WHITE
RED
ORANGE
FAN SPEED |
|
|
|
|
SWITCH |
|
|
|
|
M |
|
|
|
|
H |
|
|
|
|
C |
|
WHITE |
|
|
|
GROUND |
|
|
|
|
|
|
|
YELLOW |
|
|
BLACK |
RED |
|
|
|
ORANGE |
||
|
|
|
|
|
|
ORANGE |
ORANGE |
||
87 |
|
|
||
|
|
|
RED |
|
87a |
|
SPAL |
|
|
|
|
|
||
85 |
|
TYPE |
|
|
HIGH |
BLOWER |
YELLOW |
||
30 |
MOTOR |
|||
BLOWER |
|
RESISTER ON |
||
|
RELAY |
|
||
|
|
|
BLOWER |
|
|
|
|
|
|
PURPLE |
|
|
|
|
|
|
|
|
CONNECT TO |
|
|
|
|
KEY ON IGNITION |
|
|
AUX. |
|
SOURCE (5AMP FUSE) |
|
|
|
|
|
HEATER CONTROL |
|
|
30 |
|
VALVE |
|
|
|
|
|
|
|
AMP |
|
POTENTIOMETER |
|
|
||
|
|
CIRCUIT |
||
|
|
|
|
BREAKER |
|
|
BAT. |
|
TO BATTERY OR |
|
|
|
|
BATTERY TERMINAL |
|
|
|
|
ON STARTER |
|
|
|
|
SOLENOID. |
GROUND
RED BROWN |
ORANGE |
BLACK LT. BLUE |
FLOOR/VENT
SERVO
(REAR VIEW OF PLUG)
GREY
PURPLE
(OPTIONAL)
FOR DEFROST
DEFROST ONLY!
SERVO
(REAR VIEW OF PLUG)
NOTE ORIENTATION
OF PLUGS
BLACK/WHITE |
WHITE/ORANGE |
WHITE/BLUE |
WHITE/BROWN |
WHITE/RED |
HEATER CONTROL
VALVE SERVO
(REAR VIEW OF PLUG)
8
901229 REV C 12/15/16, INST STREAMLINE 4 KNOB CONTROL PANEL (ANOD) PG 8 OF 11
|
COLDER |
ROTARY TYPE |
LOCKWISE |
THERMOSTAT) |
|
|
ADJUSTABLE |
|
KNOB |
|
WARMER |
|
|
COUNTER |
|
|
CLOCKWISE |
|
CAPILLARY TUBE |
SLIDE TYPE THERMOSTAT |
|
TO EVAPORATOR |
|
|
COIL |
|
|
LEFT COLDER |
CAPILLARY |
|
TUBE |
||
|
||
|
TO |
|
|
EVAPORATOR |
|
|
COIL |
|
RIGHT WARMER |
CAPILARY
TUBE STICKER
|
|
MOSTAT |
|
INSERT THERKNESS |
|
||
THRUCAPILLARY |
|
OF |
|
ENTIRE |
THIS |
TUBE |
|
|
THIC |
HOLE. |
|
EVAPORATOR |
COIL. |
TOP VIEW |
EVAPORATOR |
|
OF EVAPORATOR |
|
|
|
|
|
|
INSERT THERMOSTAT |
|
|
CAPILLARY TUBE |
|
|
THRU THIS HOLE. |
|
|
ENTIRE THICKNESS OF |
|
|
EVAPORATOR COIL. |
|
|
|
|
NOTE: YOUR SYSTEM MAY HAVE A ROTARY OR SLIDE TYPE
THERMOSTAT. IF YOU ARE UPGRADING TO A NEW
CONTROL PANEL, USE THE THERMOSTAT INCLUDED
WITH THE NEW PANEL. REMOVE YOUR ORIGINAL
THERMOSTAT AND DISCARD.
AIR CONDITIONING ADJUSTMENTS:
ïTHE AIR CONDITIONER THERMOSTAT CONTROLS COIL TEMPERATURE. ROTARY TYPE THERMOSTATS ARE SHIPPED ADJUSTED FULLY COLD (CLOCKWISE), IN THE MAJORITY OF CASES THE A/C WILL OPERATE CORRECTLY AS SHIPPED.
ïTURNING THE KNOB ON THE ROTARY TYPE THERMOSTAT TO THE RIGHT (CLOCKWISE) MAKES THE SYSTEM OPERATE COLDER. MOVING THE LEVER TOWARD COLDER ON THE SLIDE TYPE THERMOSTAT MAKES THE SYSTEM OPERATE COLDER. IF THE THERMOSTAT IS SET TOO COLD THE EVAPORATOR COIL WILL
"ICE UP"- MEANING, THE EVAPORATOR COIL IS RESTRICTED WITH ICE AND COLD AIR FLOW WILL BE REDUCED.
ïTURNING THE KNOB TO THE LEFT (COUNTER CLOCKWISE) ON A ROTARY TYPE THERMOSTAT MAKES THE SYSTEM OPERATE WARMER. MOVING THE LEVER TOWARD THE RED LINES ON A SLIDE TYPE THERMOSTAT
MAKES THE SYSTEM OPERATE WARMER. THE COMPRESSOR CLUTCH WILL CYCLE OFF FREQUENTLY. THE EVAPORATOR COIL WILL NOT GET AS COLD, AND THE AIR TEMPERATURE WILL NOT BE AS COLD.
ADJUSTING A/C THERMOSTAT
1.) SYMPTOM: THE A/C WORKS WELL AT FIRST THEN QUITS COOLING. THE AIR FLOW FROM THE VENTS IS LOW, AND THE COMPRESSOR CLUTCH CYCLES INFREQUENTLY.
SOLUTION: THE THERMOSTAT IS SET TOO COLD AND THE EVAPORATOR IS "ICING UP" AND RESTRICTING AIR FLOW. ALLOW THE ICE TO MELT AND SET THE ROTARY TYPE THERMOSTAT WARMER (COUNTER CLOCK- WISE) 1/8 OF A TURN EACH ADJUSTMENT UNTIL THE SYMPTOMS DIMINISH.
ADJUST THE SLIDE TYPE THERMOSTAT IN 1/8" INCREMENTS TOWARD THE SMALLER BLUE GRADIENTS, UNTIL THE SYMPTOMS DIMINISH.
2.) SYMPTOM: A/C NEVER GETS COLD AND THE COMPRESSOR CLUTCH CYCLES FREQUENTLY.
SOLUTION: THE THERMOSTAT IS SET TOO WARM. SET THE ROTARY TYPE THERMOSTAT COLDER (CLOCKWISE) 1/8 OF A TURN EACH ADJUSTMENT, UNTIL THE DESIRED AIR TEMPERATURE IS REACHED. ADJUST SLIDE TYPE THERMOSTAT IN 1/8" INCREMENTS TOWARD COLDER UNTIL THE DESIRED AIR TEMP IS REACHED
AVOID SETTING THE THERMOSTAT TOO COLD.
3.) SYMPTOM: THE A/C NEVER GETS COLD, SOMETIMES EVEN BLOWS HOT, AND THE A/C COMPRESSOR CLUTCH INFREQUENTLY CYCLES OFF.
SOLUTION: THE HEATER MAY BE ON AT ALL TIMES. CAREFULLY FEEL THE HEATER HOSE BETWEEN THE EVAPORATOR AND THE HEATER CONTROL VALVE. THIS HOSE SHOULD NOT BE HOT IN THE A/C MODE. IF THE HOSES ARE HOT ....
A)- THE HEATER CONTROL VALVE MAY BE INSTALLED BACKWARDS. CHECK THE FLOW DIRECTION ARROW ON THE VALVE AGAINST THE ILLUSTRATION IN YOUR INSTALLATION INSTRUCTIONS.
|
B)- IF CABLE OPERATED: THE VALVE MAY BE MISADJUSTED. |
|
|
C)- IF VACUUM OPERATED: IT MAY BE GETTING VACUUM AT ALL TIMES (CHECK ELECTRIC SOLENOID). |
|
9 |
D)- THE HEATER CONTROL VALVE MAY BE INSTALLED IN THE WRONG HOSE. IT MUST BE INSTALLED |
|
IN THE HOSE COMING FROM THE INTAKE MANIFOLD ENGINE COOLANT PRESSURE PORT. |
||
|
901229 REV C 12/15/16, INST STREAMLINE 4 KNOB CONTROL PANEL (ANOD) PG 9 OF 11
|
|
|
STREAMLINE 4 KNOB |
|
|
CONTROL PANEL (ANDZ) PACKING LIST |
|
|
|
|
|
No. |
QTY. |
PART No. |
DESCRIPTION |
1. |
2 |
BUDDY CLIP |
|
2. |
2 |
#10 FEMALE RING TERMINAL |
|
3. |
2 |
FEMALE INSULATED TERMINAL |
|
4. |
1 |
7/16” FLAT WASHER |
|
5. |
6 |
7/16” SHAFT NUT |
|
6. |
3 |
||
7. |
3 |
1/4” RUBBER GROMMET |
|
8. |
2 |
6” FEMALE JUMPER WIRE |
|
9. |
3 |
LIGHT BULB |
|
10. |
1 |
ROTARY POTENTIOMETER with PIG TAIL |
|
11. |
1 |
491228 |
STREAMLINE 4 KNOB PANEL (BLACK ANODIZED) |
12. |
3 |
492016 |
KNOB ASSEMBLY, STREAMLINE 250 x 156 BLACK ANODIZED |
13. |
2 |
||
14. |
1 |
48” ADJUSTABLE ROTARY THERMOSTAT |
|
15. |
1 |
CONTROL PANEL BRACKET |
|
16. |
1 |
492017 |
KNOB ASSEMBLY, STREAMLINE 6 x 4.5 MM BLACK ANODIZED |
17. |
2 |
186890 |
POTENTIOMETER FLAT WASHER |
18. |
2 |
186892 |
POTENTIOMETER SHAFT NUT |
1 |
|
2 |
3 |
4 |
5 |
6 |
|
7 |
|
|
9 |
|
|
|
8 |
|
|
|
|
|
|
|
|
|
10 |
|
OFF
LO
MED
HI
11
15
H |
C |
|
12 |
13 |
14 |
16 |
17 |
18 |
10
901229 REV C 12/15/16, INST STREAMLINE 4 KNOB CONTROL PANEL (ANOD) PG 10 OF 11
|
CONTROL PANEL PACKING LIST |
CONTROL PANEL |
||
|
491229 |
|||
|
|
|
|
|
No. |
QTY. |
PART No. |
DESCRIPTION |
|
1. |
1 |
491229 |
STRMLINE 4 KNOB CONTROL PANEL (ANDZ) |
CHECKED BY:
PACKED BY:
DATE:
OFF LO
MED HI
H |
C |
|
901229 REV C 12/15/16, INST STREAMLINE 4 KNOB CONTROL PANEL (ANOD) PG 11 OF 11
The information below is required for social login
Sign In
Create New Account